Pengaruh Single Tuned Filter Terhadap Frekuensi Harmonik ke-3 Pada Beban Rumah Tangga 2200 VA

Main Article Content

Randy Randy
Endah Setyaningsih
Tjandra Susila

Abstract

 Home load 2200 VA is one of the non-linear loads that contains harmonic distorted waves. Harmonics is the integer multiplication periodically to the fundamental frequency. The resulting harmonics can aggravate the quality of the non-linear load, one consequence is to shorten the non-linear load life due to overheating. The resulting harmonics can be calculated with Total Harmonic Distortion. This research discusses the influence of Single Tuned Filter on 3rd harmonic frequency at 2200 VA Home load to reduce 3rd harmonic frequency value. Tests conducted in this research is testing the positive effect of decreasing the 3rd harmonic frequency on the values of and  to the value of power factor. Based on the results of the tests that have been done, decreasing the 3rd harmonic frequency on the values of  and  have a positive influence on the value of power factor. Values  and before filter fitted have significant differences than values  and  after fitted filter. The power factor value before filtering has a significant difference over the power factor value after it has been filtered.


 Beban Rumah Tangga 2200 VA adalah salah satu beban non-linier yang menggambarkan gelombang yang terdistorsi yang mengandung harmonik. Harmonik adalah perkalian integer secara periodik terhadap frekuensi fundamental. Harmonik-harmonik yang timbul tersebut dapat memperburuk kualitas dari Beban non-linier tersebut, salah satu akibatnya adalah memperpendek umur beban non-linier tersebut karena overheating yang terlalu berlebihan. Harmonik-harmonik yang timbul tersebut dapat dihitung dengan Total Harmonic Distortion. Penelitian ini membahas mengenai pengaruh Single Tuned Filter terhadap Frekuensi harmonik ke-3 pada Beban Rumah Tangga 2200 VA untuk mereduksi nilai frekuensi harmonik ke-3. Pengujian yang dilakukan dalam penelitian ini adalah pengujian pengaruh positif penurunan frekuensi harmonik ke-3 pada nilai THDV dan THDI terhadap nilai faktor daya. Berdasarkan hasil pengujian yang telah dilakukan penurunan nilai frekuensi harmonik ke-3 pada nilai THDV dan THDI memiliki pengaruh positif terhadap nilai faktor daya. Nilai THDV dan THDI sebelum dipasangi filter memiliki perbedaan yang signifikan daripada Nilai THDV dan THDI sesudah dipasangi filter. Nilai faktor daya sebelum dipasangi filter memiliki perbedaan yang signifikan daripada nilai faktor daya sesudah dipasangi filter.

Article Details

How to Cite
[1]
R. Randy, E. Setyaningsih, and T. Susila, “Pengaruh Single Tuned Filter Terhadap Frekuensi Harmonik ke-3 Pada Beban Rumah Tangga 2200 VA”, TESLA, vol. 19, no. 2, pp. 194–210, Nov. 2018.
Section
Articles

References

Associated Power Technologies, Total Harmonic Distortion and Effects in Electrical Power Systems. APT, 2011.

S.W. Blume, “Electric Power System Basics for The Nonelectrical

Professional”. Wiley-Interscience: America. (2007)

Harmonics and IEEE 519. EnergyLogix Solutions Inc.

IEEE Std. 519-1992 – Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems

I. Priyadi, “Studi Penggunaan Rangkaian Filter untuk Mengurangi Efek Harmonisa pada Lampu Hemat Energi”, Universitas Bengkulu, Bengkulu,Indonesia

Y.S. Cho and H. Cha, Single-tuned Passive Harmonic Filter Design Considering Variances of Tuning and Quality Factor. Journal of

International Council on Electrical Engineering Vol. 1 No. 1, pp 7 -13,

E. Sopyandi. “Perancangan Single Tuned Filter untuk Mereduksi Arus dengan Simulasi Program ETAP Powerstation 5.0.3”, Teknik Elektro,Universitas Indonesia, Depok, Indonesia

Abiddin. F. J,” ANALISIS UNJUK KERJA HARMONIK DIINSTALASI

LISTRIK INDUSTRI DAN UPAYA PENANGGULANGGANNYA”,

Jurusan Teknik Elektro, Sekolah Tinggi Teknologi Nasional,Yogyakarta,

Indonesia.

Widiarto. E dan Jamaah.A,”Perancangan Low Pass RC Filter untuk Mereduksi Harmonik pada Lampu Hemat Energi (LHE) 20W”, Jurusan Teknik Elektro, Politeknik Negri Semarang, Semarang, Indonesia.

Most read articles by the same author(s)

> >>