STUDI AWAL KARAKTERISTIK TEMPERATUR DAN TEKANAN PADA ALIRAN SIRKULASI ALAM DI FASILITAS UJI UNTAI FASSIP-02 MENGGUNAKAN SIMULASI CFD

Main Article Content

Ainur Roidi Rosidi

Abstract

TFASSIP-02 loop is a test facility that is used for research and development of safety technologies for future nuclear power plants based on natural law. This test facility is designed to study natural circulation phenomena caused by differences in fluid density due to temperature differences in the one-phase heat dissipation system during the simulation of heat removal from the reactor core when an accident occurs. FASSIP-02 loop consists of piping components, water heating tanks, water cooling tanks and expansion tanks. The purpose of this study was to understand the conditions of temperature change and pressure of water working fluid based on temperature changes in the heater section which were simulated on the loop geometry FASSIP-02. The research method was carried out in a simulation of Computational Fluid Dynamics using FLUENT 6.3 software. The working fluid in the FASSIP-02 loop uses water with a temperature of 27°C, the flow rate is varied 0.3 m/s and 0.45 m / s, while the temperature in the heating section is 70°C. CFD simulation results show that the increase in the working fluid temperature of the water with a flow rate of 0.3 m/s after passing through the heating section is 39°C, while the temperature increase of the working fluid of the water with a flow rate of 0.45 m/s is 36.6°C. Pressure drops at flow rates of 0.3 m/s and 0.45 m/s each occur in water working fluid before entering through WHT and after passing through the heating section. 

Article Details

Section
Articles
Author Biography

Ainur Roidi Rosidi, Universitas Tarumanagara

Pusat Teknologi dan Keselamatan Reaktor Nuklir  Badan Tenaga Nuklir Nasional (BATAN)

References

. Kudariyawar, Jayaraj Yallappa, Srivastava, Abhishek Kumar, Vaidya, Abhijeet Mohan, Maheshwari, Naresh Kumar, & Satyamurthy, Polepalle. (2016). Computational and experimental investigation of steady state and transient characteristics of molten salt natural circulation loop. Applied Thermal Engineering,99,560-571. doi: https://doi.org/10.1016/j.applthermaleng.2015.12.114.

Studi awal karakteristik temperatur dan tekanan pada aliran sirkulasi alam di … (A. Rosidi, dkk) 11

. Krishnani, Mayur, & Basu, Dipankar N. (2017). Computational stability appraisal of rectangular natural circulation loop: Effect of loop inclination. Annals of Nuclear Energy, 107, 17-30. doi: https://doi.org/10.1016/j.anucene.2017.04.012. [3]. Saha, Ritabrata, Ghosh, Koushik, Mukhopadhyay, Achintya, & Sen, Swarnendu. (2018). Dynamic characterization of a single phase square natural circulation loop. Applied Thermal Engineering, 128, 1126-1138. doi: https://doi.org/10.1016/j.applthermaleng.2017.09.092. [4]. Wang, J. Y., Chuang, T. J., & Ferng, Y. M. (2013). CFD investigating flow and heat transfer characteristics in a natural circulation loop. Annals of Nuclear Energy, 58, 65-71. doi: https://doi.org/10.1016/j.anucene.2013.01.015. [5]. Ekariansyah, Andi Sofrany, Tjahjono, Hendro, Juarsa, Mulya, & Widodo, Surip. (2016). Analysis Of The Effect Of Elevation Difference Between Heater And Cooler Position In The Fassip-01 Test Loop Using Relap5. Sigma Epsilon-Buletin Ilmiah Teknologi Keselamatan Reaktor Nuklir, 19(1). [6]. Tjahjono, H. (2017). Comprehensive Prediction of Thermosyphon Characteristics in Reactor Passive Cooling System Simulation Loop FASSIP-01 (Vol. 43). [7]. Kusuma, Mukhsinun Hadi, Putra, Nandy, Antariksawan, Anhar Riza, Koestoer, Raldi Artono, Widodo, Surip, Ismarwanti, Sri, & Verlambang, Brilian Tegar. (2018). Passive cooling system in a nuclear spent fuel pool using a vertical straight wickless-heat pipe. International Journal of Thermal Sciences, 126, 162-171. doi: https://doi.org/10.1016/j.ijthermalsci.2017.12.033. [8]. Antariksawan, Anhar Riza, Widodo, Surip, Juarsa, Mulya, Haryanto, Dedy, Kusuma, Mukhsinun Hadi, & Putra, Nandy. (2018). Simulation Of Operational Conditions Of Fassip02 Natural Circulation Cooling System Experimental Loop. Jurnal Sains dan Teknologi Nuklir Indonesia, 19(1), 40-52. [9]. Juarsa, M, Antariksawan, AR, Kusuma, MH, Haryanto, D, & Putra, N. (2018). Estimation of natural circulation flow based on temperature in the FASSIP-02 large-scale test loop facility. Paper presented at the IOP Conference Series: Earth and Environmental Science. [10]. Cyranka, Jacek, Mucha, Piotr B., Titi, Edriss S., & Zgliczy?ski, Piotr. (2018). Stabilizing the long-time behavior of the forced Navier–Stokes and damped Euler systems by large mean flow. Physica D: Nonlinear Phenomena, 369, 18-29. doi: https://doi.org/10.1016/j.physd.2017.12.010. [11]. Jiang, X. W., Studer, E., & Kudriakov, S. (2013). A simplified model of Passive Containment Cooling System in a CFD code. Nuclear Engineering and Design, 262, 579-588. doi: https://doi.org/10.1016/j.nucengdes.2013.06.010. [12]. Ge, Jian, Tian, Wenxi, Qiu, Suizheng, & Su, G. H. (2018). CFD investigation on thermal hydraulics of the passive residual heat removal heat exchanger (PRHR HX). Nuclear Engineering and Design, 327, 139-149. doi: https://doi.org/10.1016/j.nucengdes.2017.11.029.