ANALISIS PANJANG PENGANGKURAN TERHADAP KUAT TARIK MAKSIMUM MENGGUNAKAN APLIKASI MIDAS FEA NX

Main Article Content

Daniel Christianto
Nikita Audrian
Gabriella Victoria
Edison Leo

Abstract

Anchors are one of the commonly used connecting methods, that are used to connect structural elements with concrete or other materials and are used not only in new structures but also in existing structures. The installation system can be done by cast in place or post-installed. One type of post-installed anchor is an adhesive anchor which is widely used in strengthening concrete structures because of its installation efficiency. One of the factors that determine the anchor’s tensile strength is the embedment length, where the anchor transmits force from or to the surrounding concrete. The research used the finite element method using Midas FEA NX. Modeling was made with anchor diameters of 10 mm, 12 mm, 16 mm, 19 mm, concrete strength of 20 MPa, 25 MPa, 30 MPa, 35 MPa, and anchor embedding depths of 3d, 6d, 105 mm, 150 mm. Then, a tensile test is carried out on the anchors to obtain the tensile capacity value of each anchor. The analysis is carried out in nonlinear static with vertical loads in displacement approach. Based on the analysis results, it can be concluded that the deeper the anchor embedment length, the greater the anchor's tensile capacity.


Abstrak


Angkur adalah salah satu metode penghubung yang umum digunakan, tujuannya untuk menghubungkan elemen struktural dengan beton atau material lainnya dan digunakan bukan hanya pada struktur baru tetapi juga pada struktur yang sudah ada. Sistem pemasangannya dapat dilakukan sebelum (cor di tempat) ataupun sesudah beton mengeras (pasca pasang). Salah satu tipe angkur pasca pasang adalah angkur adhesif yang saat ini banyak digunakan dalam perkuatan struktur beton karena pemasangannya lebih efisien. Salah satu pengaruh kuat tarik angkur adalah berdasarkan dari kedalaman penanaman angkur, dimana angkur menyalurkan gaya dari atau menuju beton di sekelilingnya. Penelitian dilakukan dengan metode elemen hingga menggunakan Midas FEA NX. Pemodelan dibuat dengan diameter angkur 10 mm, 12 mm, 16 mm, 19 mm, mutu beton 20 MPa, 25 MPa, 30 MPa, 35 MPa, serta kedalaman penanaman angkur sebesar 3d, 6d, 105 mm, 150 mm. Setelah itu dilakukan pengujian tarik pada angkur untuk mendapatkan nilai kapasitas tarik masing-masing angkur. Analisis dalam Midas FEA NX dilakukan secara nonlinear statik dengan beban secara vertikal menggunakan pendekatan perpindahan dan mengetahui jenis keruntuhan yang terjadi. Berdasarkan hasil analisis, semakin dalam penanaman angkur maka semakin besar pula kapasitas tarik angkur.

Article Details

Section
Articles

References

Abel, D. H. (2018). Studi Eksperimental Pengaruh Kedalaman dan Diameter Pada Kuat Lekat Angkur dengan Beton Menggunakan Chemical Anchor. Universitas Katolik Parahyangan, Bandung.

Al-Fouadi, W., Mohammed, A., & Abdullah, K. (2018). Experimental and analytical study on behavior of pull-out failure of reinforcing bar embedded in concrete blocks.

Badan Standardisasi Nasional. (2019). Persyaratan beton struktural untuk bangunan gedung dan penjelasan (SNI 2847:2019).

Dewobroto, W. (2015). Struktur Baja–Perilaku, Analisis & Desain – AISC 2010. Jurusan Teknik Sipil UPH, Tangerang.

Mousavi Siamakani, S. Y., Jiradilok, P., Nagai, K., & Sahamitmongkol, R. (2020). Discrete mesoscale analysis of adhesive anchors under tensile load taking into account post-installed reinforcement. Construction and Building Materials, 262, 120778. https://doi.org/10.1016/j.conbuildmat.2020.120778

Rosyidah, A., Putra, J. W., & Saputra, J. (2022). Chemical Anchor Pullout Force Modeling with Variation of Anchor Embedment Length in Concrete and Concrete Strength. 8(September), 277–290. https://doi.org/10.22146/jcef.3769

Badan Standardisasi Nasional. (2017). Baja tulangan beton (SNI 2052:2017).

Upadhyaya, P., & Kumar, S. (2015). Pull-out capacity of adhesive anchors: An analytical solution. International Journal of Adhesion and Adhesives, 60, 54–62. https://doi.org/10.1016/j.ijadhadh.2015.03.006